Diagram of "MR Conditional" mitral valve annuloplasty ring sutured into place.
Respiratory Products - Ventilation, Intubation | Medtronic
Patients with an INR of 1.5-2.0 had a >60% reduction in bleeding events and no increase in TE compared to patients with an INR of 2.0-3.0.*. It is important to consult the full system manuals for the most updated information.
2. Indications: The Medtronic Open Pivot Aortic Valved Graft (AVG) is indicated for the replacement of diseased, damaged, or malfunctioning native or prosthetic aortic valves, where a replacement valve and replacement or repair of the aorta is required. Warning: Persons allergic to cobalt-chromium or nickel may suffer an allergic reaction specifically to the AP360 style device. FLEX H/A is a homogenous, nonporous composite of two well-known biomaterials: hydroxylapatite and silicone.
Click OK to confirm you are a Healthcare Professional. All other bileaflet aortic valve anticoagulation should be managed at an INR of 2.0-3.0. It is processed to render the tissue in the valve non-viable; it may be tissue only, or tissue attached to a metal or synthetic polymer framework.
They are classified as either bioprosthetic or mechanical.
Artificial cardiac valves may be implanted by either an open surgical or transcatheter approach. To address the issue, Medtronic Australasia is recalling resources used to select appropriately sized devices for implantation. Note green deployment catheter. PRODUCT DETAILS EXCEPTIONAL DESIGN
Avoid packing external canal with adherent dressings or applying excessive pressure. The Mosaic Porcine Aortic Bioprosthesis Model 305 is an artificial valve used to replace faulty aortic heart valves. Federal law (USA) restricts this device to sale by or on the order of a physician. Safety Topic / Subject Heart Valves and Annuloplasty Rings. MeroGelOtologic Packing is a space-occupying dressing and/or stent intended to separate mucosal surfaces, help control minimal bleeding, and act as an adjunct to aid in the natural healing process. Accelerated deterioration due to calcific degeneration of bioprosthesis may occur in: children, adolescents, young adults, and patients with altered calcium metabolism (e.g., chronic renal failure, hyperparathyroidism). Training, education, and collaboration on the treatment of mitral and tricuspid valve disease. Secondary surgical intervention to correct for a significant and persistent conductive hearing loss from prior otologic surgery, Surgically correctable injury to the middle ear from trauma, The presence of middle ear infection which could result in displacement of the implant(s), Conductive hearingloss which may be restored by non-invasive methods. The Cinch implant system capitalizes on the flexible stent to facilitate valve implantation, particularly through tight patient anatomy: Handle (234 mm length) pliant, without locknut to be used with Mosaic or Mosaic Ultra prostheses, Handle (368 mm length) pliant, without locknut to be used with Mosaic or Mosaic Ultra prostheses, Mosaic mitral obturator set (no handles, no tray), LifeLine Cardiovascular
Subsequent surgical procedures may be required to correct these conditions if possible.
Heart Valves - Surgical | Medtronic
For more information see the TGA Incident Reporting and Investigation Scheme (IRIS). Healthcare Professionals Ann Thorac Surg.
The result is a unique bioactive material which provides excellent tissue interface and can be easily trimmed with a surgical knife. For countries that use eIFUs , consult instructions for use at this website www.medtronic.com/manuals.
The Mosaic bioprosthesis is an evolution in durability and implantability, based on the proven platform of the Hancock II valve. The Evolut PRO self-expanding transcatheter aortic valve features a unique valve design with an outer wrap that adds surface area contact between the valve and the native aortic annulus to further advance valve sealing performance. Hazard alert - potential for implanting oversized valves, Information for surgeons and cardiologists, TGA Incident Reporting and Investigation Scheme (IRIS). Be alert to the issue in your clinical decision-making and consider referring the patient to a relevant specialist, if required.
This theoretical concern was not born out experimentally, so all-metal valves remain safe to scan at fields at least up to 3T. A report of the American College of Cardiology/American Heart Association Joint Committee on clinical practice guidelines. The Mosaic bioprosthesis based on more than 30 years of Medtronic tissue-valve design expertise is an excellent choice for surgeons looking for long-lasting durability, exceptional performance and implantability for aortic, mitral, and MICS procedures. Additional factors that may contribute to durability are: The benefits of AOA tissue treatment have been demonstrated through animal testing. Biomaterials, Nasal Packing & Ear Packing Healthcare Professionals
Hancock bioprosthetic valvedconduits are for the reconstruction of congenital or acquired cardiac and great vessel malformations or pathologies for right-heart applications. Your cardiac surgery destination for education, evidence, and innovation. Warning: Persons allergic to cobalt-chromium . Surgical Heart Valve Repair and Replacement With an updated browser, you will have a better Medtronic website experience.
The CG Future is an annuloplasty system for mitral valve repair, designed to predictably remodel the annulus to maintain apposition of the anterior and posterior leaflets. Indications, Safety, and Warnings Product Details Medtronic Open Pivot Aortic Valved Graft (AVG) Mosaic & Mosaic Ultra Bioprostheses.
Physiologic Fixation, our advanced tissue fixation process, to mitigate biomechanical failures and promote long-term valve durability by: Improving preservation of valve structure and leaflet function, allowing it to function similar to a native valve. Mosaic and Mosaic Ultra Bioprostheses - Surgical Heart Valves - Medtronic Valve dimensions and geometry facilitate future ViV procedures. The Mosaic Mitral Valve Bioprosthesis: A Long-Term Clinical and
Indications, Safety, and Warnings for Bioresorbable Ear - Medtronic Less information (see less).
Medtronic Neurosurgery Goleta, CA.
Aortic and Mitral Valve Surgery - Important Safety Information - Medtronic
Accelerated structural deterioration due to calcific degeneration of bioprosthesis may occur in: children, adolescents, young adults, and patients with altered calcium metabolism (e.g., chronic renal failure, or hyperparathyroidism). Avoid packing external ear canal with adherent dressings or applying excessive pressure. Update my browser now. EpiDisc is indicated for myringoplastic and tympanoplastic surgical procedures.
Caution: Federal Law restricts this device to sale by or on the order of a physician or properly licensed practitioner.
Please help keep this site free for everyone in the world! Update my browser now. Crown PRT Aortic Pericardial Heart Valve LivaNova, www.livanova.sorin.com. Copyright 2023 by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. All rights reserved.
The valve you know and trust continues to evolve Built upon the proven SAPIEN platform, the SAPIEN 3 Ultra transcatheter heart valve is designed with your patient's future needs in mind. Overview The Mosaic bioprosthesis based on more than 30 years of Medtronic tissue-valve design expertise is a great option for surgeons seeking exceptional long-term durability, excellent hemodynamics, and a smooth implanting experience. Suitable for Future Interventions Valve dimensions and geometry enable future valve-in-valve (ViV) replacements. Your use of the other site is subject to the terms of use and privacy statement on that site. Rie FC, Fradet G, Lavoie A, Legget M. Long-Term Outcomes of the Mosaic Bioprosthesis.
Carpentier-Edwards annuloplasty rings, Models 4400 and 4500, marketed from 1980 to 1983, were made of stainless steel. VALVE 310C31 MOSAIC MIT CINCH US Medical Device Identification
A xenograft (e.g., porcine or bovine heart valve) intended to be implanted in a patient during open heart surgery to repair or replace a dysfunctional mitral heart valve. The following postoperative precautionary measures are recommended: Hydroxylapatite is the basic inorganic constituent of living bone tissue. Object Info: - MRI Safety Medtronic, www.medtronic.com Various reports6-9have shown that the MB is a safe and well-performing device in the medium and intermediate terms. This website provides excerpts from our user manuals. Update my browser now.
Heart Valves Surgical. The Profile 3D annuloplasty system has a unique asymmetrical 3D remodeling ring design based on the annular geometry of normal human mitral annuli. The Contegra conduit offers a natural alternative for reconstruction or replacement of the natural right ventricular outflow tract (RVOT). Medtronic.com Contact Medtronic Terms of Use Privacy Statement Patient Implant Information Previous Versions of Manuals 2023 Medtronic It is highly unlikely, however, that anyone with mitral valve disease requiring angioplasty 40 years ago is still alive to be scanned, so I do not worry about the possibility of such a "black swan"event.
Heart Valves and Annuloplasty Rings More. Assists implantation with clear markings for proper orientation. 1.5: Safe More .
It is recommended that EpiDisc and MeroGel QuickGel Otologic Dressing be used immediately after the opening of the pouch; discard any unused portion of the device. Edwards MIRA Mechanical Valve Mitral, Model 9600, size 33 mm heart valve Similarly, a tissue graft should be employed over the stapes footplate, or alternatively, over the oval window in stapedectomy procedures to help prevent perilymph fistula or leakage of perilymph.
Important Safety Information.
The artificial valve incorporates synthetic materials and porcine heart valve tissue. Update my browser now. Product Details. Medtronic Operational Headquarters 710 Medtronic Parkway Minneapolis, MN 55432-5640 USA, Central/Eastern Europe, Middle East & Africa, Electromagnetic Compatibility Guide for Cardiac Devices, Surgical Heart Valve Repair and Replacement, Medtronic Open Pivot Aortic Valved Graft, Electromagnetic Compatibility for Cardiac Devices, California Transparency in Supply Chains Act, Information About Proposition 65 for California Customers, Digital Millennium Copyright Act (DMCA) Notification.
The asymmetrical design of Mosaic offers one wider leafletspaced at 135 with an interstrut distance of 18.4 mm. Like any ceramic material, there is some risk of breaking or cracking the implant under certain conditions. August 2020;110(2):508-515. The manufacturer is unwilling to provide an MR safety statement, so these must be considered "MR Unsafe." 310C29: Medtronic Mosaic 310 Cinch Mitral Valve, 29mm
For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use. If you have not been contacted or want to order the new materials directly, contact Medtronic Australasia on 1800 668 670.
Am J Oto. Surgeons and cardiologists should continue to follow-up with their patients as per their usual practice and in accordance with published guidelines. The surgeon must use medical judgment and consider the patients medical history prior to a decision to surgically insert a ventilation tube. Your report will contribute to the TGA's monitoring of these products. (such as Revo MRI, SynchroMed, Endeavor, Mosaic, Delta, InterStim) by Device Type (such as pacemaker, stent, otology implants, drug pump) Warning: Do not use magnetic resonance imaging (MRI) on a patient who has an implanted device until you review the following: All conditions for use for all implanted devices Contegra is an integrated valved conduit for reconstruction or replacement of the natural right ventricular outflow tract (RVOT) or replacement of a failed homograft or composite pulmonary conduit. Strength 3. To safeguard against postoperative sensorineural hearing loss, extreme care must be taken to avoid traumatizing the inner ear structures by unnecessarily contacting the inner ear structures with surgical instruments or the implant(s) or through the removal of perilymph from the vestibule. THE List - MRI Safety To prevent potential separation of the shoe component (if applicable), verify prosthesis shaft is fully seated within the shoe prior to placement. This problem has occurred at a rate of 0.33% (3.3 reports per 1000 aortic valves). AMEND Mitral Annuloplasty Ring, All Sizes Valcare Medical LTD., www.valcaremedical.com. With an updated browser, you will have a better Medtronic website experience.
Safety Info ID# Safety Topic / Subject Article Text 179: . Indications: The Medtronic Open Pivot Heart Valve is indicated for the replacement of diseased, damaged, or malfunctioning native or prosthetic aortic or mitral valves. THE List - MRI Safety Home Patients No clinical data is available which evaluates the long-term impact of the Physiologic Fixation process or the impact of AOA treatment in patients.
Society for Medical Physics of the Netherlands (NVKF).
However,the use of cartilage or other suitable autogenous tissue as an interface between the implant and the tympanic membrane should be left to the surgeons experiences and preferences.
Ear, Nose & Throat The hazard alert and recall only affect the Medtronic Mosaic Porcine Aortic Bioprosthesis Model 305 (all sizes and configurations, Standard and Ultra) and its associated sizing materials.
As a precaution against implant extrusion through the tympanum, tissue grafts should be used as an interface between the implant and the tympanum.
There is a risk of non sterile product and patient infection, in case any unutilized portions of product were to be re-used after first application. For countries that use eIFUs, consult instructions for use at this websitemedtronic.com/manuals. The Streamline family from Medtronic is designed for post-surgical temporary pacing. A Medtronic Australasia field representative will contact surgeons about the new obturator/sizer set and sizing chart. CVG EMEA Indications, Safety and Warnings | Medtronic Indications: For the replacement of malfunctioning native or prosthetic aortic valves with the option of aortic root replacement.
Cardiovascular Mosaic Mitral Bioprosthesis Model 310 is not affected.
For countries that use eIFUs, consult instructions for use at www.medtronic.com/manuals. CSF Flow Control Valve, Fixed Pressure Medtronic, Inc., www.medtronic.com. Corevalve Evolut PRO Bioprosthesis, Heart Valve Prosthesis.
Home Cardiovascular These complications could lead to reoperation, explant of the bioprosthesis, permanent disability, or death. Thus at present, most centers consider all implanted heart valves and annuloplasty rings conditionally safe for MR imaging up to 3.0T, and do not require any waiting period after surgery before they can be scanned. It is recommended that MeroGel be used immediately after opening of the pouch; discard any unused portion of the device. An investigation has found that the sizing chart and associated sizing tools (known as 'obturators' or 'sizers') may have contributed to the selection of larger-than-optimal implants. heart valve Medtronic Inc. Minneapolis, M. 1.5: Safe More. For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use. Product names on this page are trademarks or registered trademarks of Medtronic. The Duran AnCore annuloplasty system combines more than 35 years of proven technology with features that make it easy to implant.
In a prospective, multicenter, long-term follow-up observational study of 1,029 patients, the following outcomes were reported: Adverse events potentially associated with the use of bioprosthetic heart valves include: angina, cardiac arrhythmia, cardiac dysrhythmias, endocarditis, heart failure, hemolysis, hemolytic anemia, hemorrhage (anticoagulant/antiplatelet related), leak (transvalvular or paravalvular), myocardial infarction nonstructural dysfunction (obstructive pannus ingrowth, suture dehiscence, inappropriate sizing, other), stroke, structural deterioration (calcification, leaflet tear, other) thromboembolism, valve thrombosis. Beute T, Goehler M, Parker J, et al. Heart Valves Surgical Home AOA Tissue Treatment Video
Ann Thorac Surg.
Update my browser now. Note: Manuals can be viewed using a current version of any major internet browser. Avoid packing external ear canal with adherent dressings or applying excessive pressure. You just clicked a link to go to another website.
It is possible that some of the products on the other site are not approved in your region or country. Medtronic Operational Headquarters 710 Medtronic Parkway Minneapolis, MN 55432-5640 USA, Central/Eastern Europe, Middle East & Africa, Electromagnetic Compatibility Guide for Cardiac Devices, Biomaterials, Nasal Packing & Ear Packing, View indications, safety, and warnings for MeroGel, View indications, safety, and warnings for the IndigoOtologic Drill, View indications, safety, and warnings for the IPC, View indications, safety, and warnings for the NIM, OSSICULAR PROSTHESES (MIDDLE EAR AND STAPES IMPLANTS), Electromagnetic Compatibility for Cardiac Devices, California Transparency in Supply Chains Act, Information About Proposition 65 for California Customers, Digital Millennium Copyright Act (DMCA) Notification.
The Mosaic Porcine Aortic Bioprosthesis Model 305 is an artificial valve used to replace faulty aortic heart valves. The EpiDisc TM Perforation Patch Kitis indicated for use during myringoplastic surgical procedures. With an updated browser, you will have a better Medtronic website experience. Healthcare Professionals
Design is based on CT data from functional human tricuspid valves. Medtronic Xomed ossicular prostheses are indicated for the functional restoration of sound energy conduction in the middle ear as reconstructive devicesor artificial replacement for the natural ossicles of the middle ear. Products
Healthcare Professionals AccessGUDID - DEVICE: MOSAIC (00613994689061)
Instructions for Use. Medtronic Operational Headquarters 710 Medtronic Parkway Minneapolis, MN 55432-5640 USA
Indications, Safety, and Warnings.
It is possible that some of the products on the other site are not approved in your region or country. Update my browser now. This device has been approved as a humanitarian use device (HUD) in the United States. On this page: Information for consumers | Information for surgeons and cardiologists | Information for health professionals | Additional information | Reporting problems. Products With an updated browser, you will have a better Medtronic website experience. March 2018;105(3):763-769. Contraindications: None known . For countries that use eIFUs, consult instructions for use at this website www.medtronic.com/manuals.
Contraindications: The AVG is contraindicated in patients unable to tolerate anticoagulation therapy. Update my browser now. Mosaic and Mosaic Ultra Bioprostheses. Serious complications may arise either during or after surgery which may result in irreparable damage to these otologic structures and their functions causing irreversible partial or total loss of hearing.